SUPPLIER TEST REPORT · ENGLISH SUMMARY

PVC flooring test report XJ2024B03A00730

English-language summary of a Chinese type-test report for a 2.0mm PVC flooring sample. The original Chinese report remains the controlling document.

Report numberXJ2024B03A00730
Issued23 May 2024
SamplePVC flooring, 2.0mm
Test typeType test

REPORT DETAILS

Tested sample and issuing laboratory

The report was issued by China Testing & Certification International Group Co., Ltd. (CTC), National Building Materials Testing Center. It was commissioned by and names Hangzhou Xuli New Building Materials Co., Ltd. as the client and producer.

Declared dimensions

20m length, 2m width, 2.0mm total thickness, 0.4mm wear layer.

Mass

Declared mass per unit area: 3050 g/m².

Batch

Production date / batch: 6 April 2024 / 240406.

Test period

17 April to 22 May 2024; report issued 23 May 2024.

Sample quantity

Three rolls submitted for type testing.

Applicable product

This result relates to the submitted sample; other colours, batches and specifications require separate confirmation.

STANDARDS REFERENCED

Test and classification standards

TEST RESULTS

Translated results table

No.Test itemRequirement shownResultSingle-item conclusion
1AppearanceNo cracks, breaks or delamination; only slight creases, bubbles, missing print or pattern distortion; no obvious registration offset, colour difference or contaminationNo cracks, breaks, delamination, creases, bubbles, missing print or pattern distortion; no obvious registration offset, colour difference or contaminationPass
2LengthNot less than declared value20010 mmPass
3WidthNot less than declared value2008 mmPass
4Total thickness deviationAverage +0.13/−0.10mm; individual average +0.15/−0.15mmAverage −0.01mm; individual +0.04/−0.04mmPass
5Wear layer thickness deviationAverage ±0.10mm; individual average +0.05/−0.05mmAverage −0.02mm; individual +0.01/−0.01mmPass
6Mass per unit area tolerance+13%/−10% of declared value+5%Pass
7Dimensional change after heating≤0.40%Longitudinal 0.10%; transverse 0.11%Pass
8Curling after heating≤8mm0mmPass
9Colour fastness≥ grade 6> grade 6Pass
10Residual indentation≤0.10mm0.01mmPass
11FlexibilityNo crackingNo crackingPass
12Chair caster testNo damageNo damagePass
13Abrasion — volume loss FvClass T, ≤2.0mm³1.5mm³Pass
14Peel strengthNo pass/fail requirement shown50 N/50mm longitudinal and transverseReported value
15Stain resistanceNo pass/fail requirement shownGrade 0 for marker and iodine, 2-hour cotton clothReported value
16Slip resistanceNo pass/fail requirement shownR11 at 19.5°Reported value
17Volatile content≤40g/m² for non-foamed glass-fibre reinforced floor coverings12.0g/m²Pass
18Vinyl chloride monomer≤5mg/kgNot detected (<0.1mg/kg)Pass
19Soluble lead≤20mg/m²0.88mg/m²Pass
20Soluble cadmium≤20mg/m²4mg/m²Pass
21Reaction to fireGB 8624-2012 B1 (C-s1, t0)CHF 6.4kW/m²; flame-tip height <150mm; smoke production 375% × min; smoke toxicity ZA1Pass
This page is an English information summary, not an English-language certificate issued by the testing laboratory. The original Chinese report controls in case of discrepancy. Results apply only to the submitted sample and batch. Other colours, constructions, thicknesses and production batches must not automatically be represented as covered.